| AIChE

UltraScan VIS

The UltraScan VIS is a high-performance color measurement spectrophotometer that measures the full range of human color perception in seconds. It easily measures both reflected and transmitted color as well as transmission haze, and meets CIE, ASTM and USP guidelines for accurate color measurement. Spectral data are reported every 10 nm and tristimulus color calculations are performed from 360 to 780 nm as recommended by the CIE.

ORCA Sonar Series Interface level transmitter

The ORCA Sonar Series Interface level transmitter provides a wide range of performance-enhancing sonar transducer frequencies to yield comprehensive and continuous interface level measurement. Featuring industrial scum-cleaning mechanisms that require virtually no maintenance, the ORCA Sonar Series’ transducers are continually cleaned, allowing for efficient and accurate measurements up to 100 ft.

Type 8205 pH controller

Offering on/off and continuous process control, the Type 8205 pH controller combines a flat glass sensor and PID-controller/display within a single, splash-proof, plastic NEMA 4 enclosure. It can be integrated with the sensor or remote via a panel or wall mount. As an added feature, the pH controller indicates when the probe is 50% and fully expired when calibrating. The fittings are available in stainless steel, brass, PVDF, PP and PVC, with process connections that include threaded, TriClamp, true union and sanitary.

LCB Series of compact linear actuators

The LCB Series of compact linear actuators incorporates a low-friction, dry-running sliding bearing carriage that provides long, reliable travel life — even at 100% duty cycle. Coupled with the manufacturer’s motors/controls, the actuator series offers a fully programmable, high-performance solution at a competitive price, while reducing space requirements. Low carriage mass and a steel-reinforced timing belt enable high acceleration and sustained velocity.

Ultima X Series Sensor X-change program

The Ultima X Series Sensor X-change program is a sensor-replacement service that supplies users with replacement calibrated sensor modules when they are needed, on demand. Sensors arrive prior to the Ultima X Monitor’s scheduled calibration date for easy installation and minimal downtime. Simply change out the old sensor with the new, perform a gas check, and the system is operational. 

Rosemount MultiVariable 8800 vortex flowmeter

The Rosemount MultiVariable 8800 vortex flowmeter combines this firm’s proven vortex technology with a temperature-compensated mass flow output directly from the meter to reduce process variability. Unlike traditional designs that integrate the vortex and temperature sensor into the same assembly, this flowmeter has isolated, independent vortex and temperature sensors, allowing both sensors to be verified or replaced independently without breaking the process seals. This eliminates process shutdown for verification of the temperature sensor.

Micro-Trak 101 Series high-performance digital mass flowmeter

With state-of-the-art sensor technology and highly engineered direct-acting valve design, the Micro-Trak 101 Series high-performance digital mass flowmeter accurately measures and controls mass flows of gas previously thought by scientists to be too low for a reliable reading. The flowmeter is specifically designed for flow ranges under 4 cm3/min with a minimum controllable mass flowrate of 0.1 cm3/min. Excellent accuracy (±1.0% of full scale) and repeatability (±0.2%) coupled with unsurpassed instrument stability offer users an instrument they can consistently depend on.

AC Sulfur SIMDIS analyzer

In only eight minutes, the AC Sulfur SIMDIS analyzer reports the sulfur boiling-point distribution of petroleum products having a final boiling point of 450°C (850 °F) or lower at atmospheric pressure. The device is based on the Agilent Technologies 6890 Series GC with electronic pneumatics control configured with: accelerated SIMDIS ASTM D 2887 application; flame ionization detector (FID); and automatic liquid injector. To determine the sulfur components present in the sample, the analyzer uses a sulfur chemiluminescence detector (SCD), which offers excellent sensitivity.

Model 5100-NCM

The Model 5100-NCM offers a highly reliable and cost-effective method for quickly and accurately measuring moisture in natural gas. The device has a detection limit of 5 ppmv and an operating range from 5 to 2,500 ppmv. It is accurate to less than 2% of reading or ±4 ppmv, whichever is greater. The laser-based analyzer features compact, fully enclosed optics and sample conditioning, on-board moisture verification, and all digital processing. The rugged, compact unit is available in an IP65 and NEMA 4 enclosure with both Modbus and Ethernet analog and digital connectivity.

UltraScan PRO

The UltraScan PRO measures both reflected and transmitted color and meets CIE, ASTM and USP guidelines for accurate color measurement. The instrument scans from 350 nm to 1,050 nm in seconds and its 5-nm optical resolution enables precise measurement of colors with sharp cutoff characteristics. The D65 illumination source is calibrated in the ultraviolet region for the accurate measurement of whitening agents. In addition to color and spectral data, metrics such as APHA (Hazen), Saybolt, Gardner Scale, ASTM D 1500, Yellowness Index, Whiteness Index and Transmission Haze can be quantified.

Pages

Subscribe to AIChE RSS