March 2012 | AIChE

You are here

March 2012

Firm Provides Air Pollution Control Retrofit Services

This company provides services for retrofitting emission control equipment on existing waste-to-energy and industrial boiler installations. The retrofit services center on the installation of the firm’s spray-dry scrubber systems for controlling acid gases emitted from incinerators and boilers. Other equipment, such as electrostatic precipitators or fabric filters, may also be used in conjunction with the scrubber or as stand-alone systems.

Advantech Adam 5000/TCP

The Advantech Adam 5000/TCP enables the integration of this firm’s data acquisition product with state-of-the art communications technology that uses Ethernet (TCP-IP) as a transmission medium. The unit can be used with the EMC Station Manager CEMS/DAS and EMC Station Manager data logger software for ambient air quality and meteorological monitoring, thus benefitting from high data rates that are inherently possible in Ethernet communications.

Model 2020 Chemiluminescent NOx Analyzer

The Model 2020 Chemiluminescent NOx analyzer measures from 10 ppm or lower up to 500 ppm of NO, NO2, and NOx with a resolution of 0.01 ppm. A dual-range version is also available offering 0–500 ppm and 0–3,000 ppm. The analyzer has been developed specifically to address the performance requirements of the low NOx market with respect to drift, noise, and elimination of interference from CO2 and water. All digital electronics provide high accuracy and less noise. The front-panel display of converter temperature and chamber pressure allows visual confirmation of operating parameters.

Sensor-e Series of Gas Analyzers

The Sensor-e series of gas analyzers use proven analytical techniques, coupled with state-of-the-art microprocessor technology to provide accurate and dependable gas measurements. The multitasking software gives realtime indication of a large number of operational parameters and provides automatic alarms if diagnostic limits are exceeded. All instruments of the Sensor-e series include an extensive built-in data acquisition capability using the analyzer’s internal memory.

Enviance System

The Enviance System is an Internet-based system for the collection, distribution, analysis and reporting of environmental, health and safety (EHS) data and information. It offers a comprehensive, standards-based platform for flexible, cost effective EHS compliance management. Because of the attention to data portability, the Enviance System allows firms to fully configure the system to meet their specific requirements and complete end-to-end compliance needs.

IMPACT is a Software System for the Management of Environmental Data and Related Processes

Specializing in converting raw data into useable information, IMPACT is a software system for the management of environmental data and related processes. Data can be entered via a user-friendly, web-based interface or IMPACT’s data import tool. Streamlined reporting and graphing tools, systematic action tracking and automatic e-mail notification, as well as escalation features allow for a responsive management of environmental processes. IMPACT offers a broad range of functional content that can be applied across a wide range of industries.

Firm Offers Toxic Air Pollutant Analysis and Monitoring

Located in Ventura, CA, this full-service air-quality laboratory provides high-quality and cost-effective analysis of toxic air pollutants and monitoring to industry and government agencies. Established in 1993, the firm is equipped with a complete inventory of modern state-of-the-art laboratory equipment. Its staff has made many professional contributions through published literature and is active in ongoing research. Atmospheric Analysis & Consulting (AAC)

QICPIC Unit

The QICPIC unit offers size and shape with image processing of the highest order from 1 µm to 10,000 µm. Using a pulsed light source with sub-nanosecond illumination, QICPIC provides up to 500 frames/sec of 1024 × 1024 pixels, 3:1 thru 1:10 ranges, providing parameters of size and shape including area-equivalent circle, boundary rectangle, chord length, sphericity, Feret & Martins diameters.

PH12 PharmASep is a 12-in. Filter Dryer

All the machinery and controls necessary to operate this aseptic self-contained laboratory filter dryer are mounted on an easy-touse mobile cart. Only 4-ft high × 4-ft wide × 22-in. deep, the PH12 PharmASep is a 12-in. filter dryer for batch processing of up to 1 kg. It will fit under a standard 60- in. exhaust hood, yet includes motor control pneumatics for discharge cylinder actuation, vacuum and nitrogen flow instrumentation, quick disconnects and storage space for screens.

Isolator System Protects Against Highly Potent Products

Designed to protect operators against toxic vapors and materials, this isolator system is equipped with an integrated vacuum drying oven and a pressure nutsch. It is inerted with nitrogen, and the oxygen levels are less than 1%. The product can be loaded through RTP ports on the side of the isolator or direct through a feed tube into the pressure nutsch. Filtration of the product can be done in the pressure nutsch, after which it is scooped onto trays. that are placed in a vacuum drying oven.