GENESYS 10S Vis, the GENESYS 10S UV-Vis, and the BioMate 3S spectrophotometers

The GENESYS 10S Vis, the GENESYS 10S UV-Vis, and the BioMate 3S spectrophotometers provide instrument control using embedded software that is strong enough for demanding analysis, but simple and straightforward enough for handling routine samples. They feature a front-panel USB port for method and data storage on removable memory devices, as well as printer and computer connectivity. Their easy-to-read liquid crystal display (LCD) is backlit for lower power usage and longer product life. The user-friendly software is driven from an integrated, chemical-resistant keypad.

FTIR spectroscopy gas-analysis system

This open-path Fourier transform infrared (FTIR) spectroscopy gas-analysis system monitors air to simultaneously detect, identify and measure a wide range of compounds.†Analysis is performed onsite through a continuous sampling path of up to 1,000 m. The analyzer is coupled to a control PC via a standard ribbon cable or a long-range fiber-optic link. For extended sample paths, the analyzer can be mounted to a 10-in. Newtonian telescope with a tripod. A high-energy infrared source module is located on the opposite end of the sample path.

Dualstream wet gas flowmeters

Dualstream wet gas flowmeters provide environmentally safe, reliable and universally accepted monitoring of total pressure, differential pressure and temperature. They are designed for direct installation at a wellhead or subsea gathering line, and have a typical lifespan of more than 20 years. The manufacturer customizes each meter to ensure its compatibility with other project equipment, such as remotely operated vehicles, subsea trees, gathering lines, available power, and communication devices.

NewClassic balance range

The NewClassic balance range has a robust metal housing that provides reliable protection and resistance to chemicals. Its user interface allows for intuitive operation, with new SmartKeys that offer direct access to preferred applications. Its high-contrast display makes results easier to read, compared with the Classic model this product replaces. Cleaning the balance is simple, requiring only 30 s to dismantle the glass panels and draft shield. It features built-in shock and overload protection to extend product life.

Oakton benchtop pH meter

The Oakton benchtop pH meter measures pH, mV, and temperature and has a liquid crystal display (LCD) that provides clear instructions for setup, measurement, and calibration. It provides up to five customizable calibration points and stores up to 100 readings, with real-time stamping, either manually or automatically at programmable intervals. The backlit 20-character alphanumeric two-line LCD prompts the user during measurement and calibration, and an advanced setup mode allows the meter’s parameters to be customized.

Humidity Sensor Evaluator (Model HSE)

The Humidity Sensor Evaluator (Model HSE) displays, monitors, and logs relative humidity (RH) and dry-bulb and dew-point temperature readings of resistive and hybrid capacitive humidity sensors via a computer’s USB port. Its software includes RH sensor response curves for hybrid capacitive sensors, such as the manufacturer’s HC-610. It is compatible with Windows 2000, XP and Vista, and requires either a USB 2.0 or a USB 1.2 port. It includes a humidity/dew-point calculator, two relative humidity sensors, and a thermistor.

CPG 1000 digital test gage

The CPG 1000 digital test gage has an accuracy of 0.05% of full scale. With 18 selectable pressure units, it can handle virtually any test gage need, and is suitable for applications in calibration service, instrument and control workshops, laboratories, and quality assurance. Its rubber boot and stainless steel construction for the case and all wetted parts make it rugged and durable. The instrument features a convenient, user-adjustable reading sample rate that can be matched to the type of measurement required, allowing up to 10 measured values each second.

FineAlyzer

The FineAlyzer measures and analyzes dust particles in accordance with ASTM procedures to avoid  vigorous movement or friction of pellets during the fines separation process. The technology is based on the principle that unwanted dust and fines will typically adhere to larger pellets and will be removed by rinsing the test sample with a liquid (preferably demineralized water). This process washes away dust and fines into a beaker. Particles are then poured into the filter collection unit, which separates the fines from the water.

ToughMeter Series 270

ToughMeter Series 270 analog panel meters are designed to withstand harsh environments. They are available in 2.5-in. and 3.5-in. models, and have an accuracy of 2% DC and 3% AC. The meters have all-metal cases and polycarbonate windows, gasket-sealed bezels, terminals, and zero regulators that ensure dust and moisture protection to International Protection (IP) 66 code. They are available with either pivot and jewel or taut band suspension. 

TNTplus Reagents

\TNTplus products work with the manufacturer’s DR 2800 portable and DR 5000 UV-Vis spectrophotometers to increase their productivity and minimize analytical errors. This line of reagent sets now includes copper, high-range nitrite, and mercury-free chemical oxygen demand (COD) testing kits. All three versions are suitable for use in wastewater applications, and the copper model is appropriate for testing potable water. TNTplus features barcode scanning, which enables automatic method and wavelength selection with the insertion of a vial.