(606f) Supercritical Carbon Dioxide Sterilization of Liquid Foods Using a Membrane System | AIChE

(606f) Supercritical Carbon Dioxide Sterilization of Liquid Foods Using a Membrane System

Authors 

Novak, J. S. - Presenter, American Air Liquide


Supercritical carbon dioxide (scCO2) at greater than 31.1oC and pressures exceeding 7.38 MPa exists in a dense liquid state where the CO2 retains the lower surface tension of a gaseous phase and the increased solubility of a liquid phase. This supercritical state enables CO2 to extract various organic and inorganic molecules while inactivating numerous microorganisms. This technology has been enhanced using a microporous polypropylene membrane contactor system to saturate pumpable liquids rapidly with dense CO2. The dense CO2 is continuously recirculated without depressurization. The nonthermal process effectively inactivated a wide range of spoilage and pathogenic vegetative microorganisms, while spore-forming microorganisms required temperatures exceeding 45oC following membrane CO2 saturation. Desired changes in product flow rates necessitated consistent control of CO2 supply in order to balance the required product microbial reductions. The (scCO2) process was found to be non-toxic to the food being processed, capable of retaining fresh juice flavors, economic, and without solvent disposal problems.