Micro Motion F-Series compact Coriolis meters

The Micro Motion F-Series compact Coriolis meters are now available with additional digital protocols and Smart Meter Verification, an easy-to-use tool that monitors the structural and measurement integrity of the meter. These new capabilities are enabled by connectivity to the enhanced core processor and 2400S transmitter, both powered by Micro Motion MVD (multivariable digital) processing technology, which provides faster meter-response time. The 2400S transmitter option also enables DeviceNet and Profibus-DP communication protocols in an extremely compact package.

PRX line of proximity switches

The PRX line includes three different series of proximity switches. PRX-100 Series high-performance, moisture- and corrosion-resistant proximity switches are made from a modified polyphenylene oxide (Noryl). They are UL 508 listed and are designed to be used as safety switches. PRX-300 Series safety switches have a glass-filled nylon housing and are corrosion-resistant. They provide long-lasting performance and are easy to install in a variety of applications, including security systems, door interlocks, safety interlocks, position indication, and equipment automation.

Viatran networking system

The Viatran networking system (VNS) enables centralized wireless monitoring of sensors placed throughout any facility where measurement is critical. The VNS consists of the Viatran remote device (VRD) and the Viatran Hub (VHub). The VHub serves as the communication link for up to 10 VRDs. Each VHub sends the data to a flow computer, supervisory control and data acquisition (SCADA) system, or distributed control system. VRDs can be either process- or pole-mounted, and are powered externally or by an internal nonrechargeable lithium-ion battery that lasts at least one year.

DataBus cables

These low-capacitance DataBus cables for Foundation Fieldbus applications have improved temperature and use ratings, as well as expanded multi-pair capabilities. Their design and robust construction ensure consistently reliable performance and provide installation flexibility in diverse industrial environments, such as outdoor installations and sites that require multiple or extended cable runs. The 3076F – Type A single-pair cable carries 300 V, and has the manufacturer’s Beldfoil shield and a cold-bend temperature rating down to –40°C (as per UL 1581).

Signet 8550 flowmeter

The Signet 8550 flowmeter converts the signal from a flow sensor to a 4–20-mA signal for long-distance transmission. It features a choice of single or dual input/output, as well as two optional relays for process control, and scalability for almost any flow range or engineering unit. The flow-meter is available in three packaging options: integral/pipe, universal field mount, and panel installation. It has an operating temperature range of–10°C to 70°C (14°F to 158°F), and its National Electrical Manufacturers Association (NEMA) 4X enclosure has a self-healing window.

OriMaster

The OriMaster differential-pressure orifice flowmeter reduces installation costs by 50% because users do not need to install a separate manifold, transmitter, and impulse piping. This compact, one-piece unit is pressure-tested and configured during production, eliminating most of the problems normally associated with sizing, selection, installation and operation of conventional configurations. The flowmeter’s centralization tool ensures that the meter is correctly positioned in the pipeline. Both models are suitable for use with clean liquids, gases and steam in line sizes from 1 in.

9901 family of chambers

The 9901 family of high-quality chambers enables external mounting of level measurement and control instrumentation on process vessels. External mounting allows easy isolation of a particular instrument for routine maintenance or calibration, as well as for the fitting of instrumentation to vessels having internal structures. The units can also act as stilling chambers for liquid surfaces that are prone to turbulence. The chambers’ design is fully compliant with the European Union’s Pressure Equipment Directive (PED) and the American Society of Mechanical Engineers (ASME) B31.3 standard.

True Wireless universal monitors

True Wireless universal monitors can detect gases in virtually any application. They are capable of monitoring and transmitting data using a variety of wireless communications options, including: an ISA 100.11a 2.4-GHz mesh network; ultra-high-frequency/very-low-frequency (UHF/VHF) radio; general packet radio service (GPRS) cellular radio; and low-Earth-orbit satellite. The units are equipped with 4–20-mA output and alarm relays, and meet the requirements of both Class I, Div. 1 Underwriters Laboratories (UL) 1203 and Canadian Standards Association (CSA) 22.2 No. 30 standards.

IONizer industrial wireless networking appliance

The IONizer industrial wireless networking appliance uses the manufacturer’s IONosphere and ION system to integrate wireless sensor network gateways based on either ISA100.11a or WirelessHART standards. Its 802.11 (WiFi) radios support other industrial wireless applications, such as mobility, location, video, and communications, as well as provide efficient, wireless backhaul of sensor data. This integration allows transmission of real-time sensor data from devices instrumented with ISA100 or WirelessHART-based sensors to the ION Condition Monitoring application.

Sitrans P280 and Sitrans TF280 transmitters

The Sitrans P280 transmitter for pressure measurement and the Sitrans TF280 transmitter for temperature each feature a WirelessHART interface and a backlit graphical display, and they are easily operated via push-buttons. They are supplied with an integrated battery that lasts at least five years, and the amount of power remaining is displayed in terms of days left. The Sitrans AW200 adapter allows the manufacturer’s other process instruments without WirelessHART interfaces to be integrated into WirelessHART communications.

Pages

Subscribe to AIChE RSS