catASium T

The catASium T family consists of proprietary, patentpending ligands for the production of special enantiomerically pure substances essential for the manufacture of active ingredients in the pharmaceuticals industry. It is especially useful for the enantioselective hydrogenation of poorly substituted enamides and beta-amino acid precursors, and displays unusually high selectivities for these syntheses. catASium T is based on terpenes like camphor, which makes it easily accessible.

KALCRET-S Sprayable Compound

This spray system applies KALCRET-S wear compound to large surfaces quickly and reliably to reduce wear and abrasion, and handle high temperature. With the new spray technique, highstrength KALCRET-S can be sprayed horizontally and vertically to achieve a jointless lining. The sprayed-on surface can be worked to attain a smooth surface. KALCRET-S is a mixture of hard aggregate materials ranging in size from 0–4 mm and consisting of bauxite or corundum (depending on application), cement binder and micro silica. Defined amounts of steel fibers add structural strength.

Heaters

This new line of heaters uses direct steam injection to rapidly and accurately heat water and water-based slurries in a variety of process applications, such as boiler feedwater preheating, heating fibrous slurries for pulp stock and biomass treatment, paper-starch processing, sanitization and tank cleaning, anaerobic treatment of organic waste, and others. By using all of the sensible and latent heat of steam to heat the fluid, these systems can provide heating equal to that of an indirect heat exchanger with 20–30% less energy consumption.

Lab Companion SKC Series Shakers

The Lab Companion SKC Series high-capacity, high-speed shakers have a newly engineered drive mechanism, enabling the uniform shaking of flasks, tubes and bottles at high loads at high speeds. A large selection of models is available with speeds up to 500 rpm and a maximum orbit of 2.8 in. (70 mm), depending on platform size and stroke diameter. Programmable motion control, LED displays, unbalanced load sensors, and self-protecting cut-off function make these shakers versatile and safe.

Biochrom Asys Expert Plus

The Biochrom Asys Expert Plus is a standalone multi-channel microplate reader that enables life science researchers to run a variety of microplate assays in parallel. The device can accommodate flat-, round-, or V-bottomed plates, and can store up to 120 methods and the results of up to 100 plates. Four shaking modes ensure complete mixing of solutions, allowing cells to stay in suspension, homogenizing colored solutions, and providing an equal, stable liquid meniscus in all wells.

Apex line of personal air-sampling pumps

The Apex line of personal air-sampling pumps has been expanded to include two intrinsically safe versions — the Apex Standard I.S. and the Apex Pro I.S. Fully compliant with ATEX 100 (94/9/EC) and UL 913 ANSI standards, the new versions allow occupational hygienists and specialists to carry out personal and area sampling for gases, vapors, fumes and dusts in hazardous, classified areas where potentially explosive environments may be present. When used with a low-flow adapter assembly, the pumps have flowrates between 5 and 200 mL/min.

Flame 100 Safety Burner

The new Flame 100 Safety Burner is said to provide a safe alternative to traditional Bunsen or alcohol burners for laboratory applications. The 15-mL precision flame allows for safe sterilization of microbiological instruments. The device is activated by the push of a button and requires no match or pilot flame. Alternatively, the burner can be activated via foot pedal or external infrared motion sensor. Flame size and intensity can be adjusted. The burner is suitable for fixed natural gas and propane/butane gas supplies and gas cartridges or cylinders.

Gap Gages

Gap Gages ensure that instrumentation tube fittings are sufficiently tightened. They are particularly useful for fittings in hard-to-reach locations and in systems where inadequate tightening could result in dangerous or expensive consequences. Once the instrumentation tube fitting has been installed, but prior to system pressurization, the Gap Gage is inserted between the fitting nut and the body hex. If the gage will not fit in at any point of the gap, the connection has been properly made up and no additional tightening is necessary.

Westfall Model 3000 flow conditioner

The Westfall Model 3000 flow conditioner can be mounted directly into a piping system to resolve flow turbulence issues with minimal head loss. It has four leading tabs and four anti-swirl plates that suppress turbulence and swirl. This design achieves a fully developed velocity profile within 8 diameters downstream. It is available in sizes from 0.5 in. to 120 in. dia., and measures 2 diameters long. It is easy to install and requires almost no maintenance.

LS 13 320 particle size analyzer

The LS 13 320 particle size analyzer takes high-resolution, reproducible measurements of particles sized from 0.017 to 2,000 µm — a wider range than other laser-based instruments. It features the Tornado dry-powder dispersing system that keeps sample particles intact, and many detector and sample measurement options. Its standard analytical tools include Rosin-Rammler and Folk and Ward Phi methods. It has reverse Fourier optics incorporated into its patented fiber-optic spatial filter system, which helps to optimize light-scattering measurement.