Control valves for low flows of liquids, even of low viscosity, must be sized to take into account laminar or transitional flow in the valve trim.
We have found that the equation below allows the accurate sizing of control valves with seat-guided type trims for laminar, transitional and turbulent flow:
A single new parameter is used to adjust the sizing of families of valve trims of similar geometry, for viscosity dependence in the laminar and transitional regions.
This new parameter has a value of approximately 0.14 for seat-guided annular needle-type trims such as those used in Badger Research Control Valves and for Jordan LowFlow control valves for trims of Cv. 0.06 and smaller. A single Samson valve of similar trim type was tested and found to have an of 0.18, which we suggest to use for valves of similar design for conservative trim sizing in the absence of other data. We found to be approximately constant with varying stem position for trims of this geometry.
For seat-guided vee-groove control valve trims manufactured by Emerson (Baumann), the value of is approximately 0.06 at full open, and tends to smaller values as the valve is closed.
This equation can be solved to be explicit in Q and tends to the normal turbulent flow Cv sizing equation when the product is sufficiently small.
Checkout
This paper has an Extended Abstract file available; you must purchase the conference proceedings to access it.
Do you already own this?
Log In for instructions on accessing this content.
Pricing
Individuals
AIChE Pro Members | $150.00 |
AIChE Graduate Student Members | Free |
AIChE Undergraduate Student Members | Free |
AIChE Explorer Members | $225.00 |
Non-Members | $225.00 |