(151a) The Study of Thermal Hazard Evaluation of Polymerizing Substances at Storage
AIChE Spring Meeting and Global Congress on Process Safety
2017
2017 Spring Meeting and 13th Global Congress on Process Safety
Global Congress on Process Safety
Japan's Process Safety Progress
Wednesday, March 29, 2017 - 8:00am to 8:30am
Standard thermal hazard evaluation for self-reactive substances is the estimation of temperature rise under adiabatic condition by using the kinetics parameters that calculated from result of thermal analysis. These materials begin polymerization reaction after polymerization-inhibitor consumes. So a presence of polymerization-inhibitor in the liquid influences very big for thermal stability. Therefore there is possibility that thermal behavior of polymerizing substances is different, if the polymerization-inhibitor amount and the heating history for experimental sample, and the atmosphere at experiment are different. So wrong evaluation is sometimes carried out because correct kinetic parameters cannot be obtained when standard evaluation is applied.
For example, polymerizing materials begin polymerization reaction at room temperature, but there are cases that onset temperature of these materials with inhibitor which is obtained by thermal analysis is higher than 100â. Therefore because there is a possibility of the underestimate by using standard thermal evaluation techniques, we will study about the evaluation technique which considered material reaction mechanism. At first, thermal analysis were carried out under different experimental condition to confirm the difference of thermal behavior. A consumption mechanism of polymerization-inhibitor was considered from result of thermal analysis, and appropriate experimental condition for thermal hazard evaluation of polymerizing materials was found. Next the method to evaluate time until polymerization reaction begins was considered. As polymerization reaction occurs after polymerization-inhibitor disappeared, it's possible to regard induction time as time until polymerization-inhibitor is consumed. So to obtain induction time, an acceleration test by thermal analysis and a short storage test were carried out. And from relation between the temperature and induction time, the way to estimate induction time by the storage temperature was considered.
In our presentation, the study of thermal analysis method that considered a polymerization-inhibitor consumption mechanism, and estimation of induction time to polymerization reaction will be presented. Polymerizing substance is designated by UN transport of hazardous goods. Therefore this study is very useful for dangerous goods judgment.
Topics
Checkout
This paper has an Extended Abstract file available; you must purchase the conference proceedings to access it.
Do you already own this?
Log In for instructions on accessing this content.
Pricing
Individuals
AIChE Pro Members | $150.00 |
AIChE Graduate Student Members | Free |
AIChE Undergraduate Student Members | Free |
AIChE Explorer Members | $225.00 |
Non-Members | $225.00 |