Go To AIChE CEP Home CEP Log On Contacts Sitemap
 
My AIChE

Product Vendor Index


Universal Flow Monitors, Inc.

www.flowmeters.com
Contact this vendor

P420 Series plastic, vortex-shedding flowrate transmitters
P420 Series plastic, vortex-shedding flowrate transmitters have no moving parts that can stick, bind, or become coated. They can handle fluids with viscosities to 4.5 cP or 50 SUS. In certain models, wetted parts are constructed entirely of polyvinyl chloride (PVC) or chlorinated PVC (CPVC) for improved heat resistance. PVC and CPVC units are available in standard pipe sizes and flowrates: 0.375 in., 6 gal/min (22.7 L/min); 0.5 in., 12 gal/min (45.0 L/min.); 0.75 in., 25 gal/min (95 L/min); 1.0 in., 50 gal/min (190 L/min); 1.5 in., 100 gal/min (380 L/min); and 2.0 in., 200 gal/min (750 L/min). The P420 models with the CPVC body and sensor transmit hot water or other fluids with a maximum operating temperature of 180°F, compared with a 140°F maximum for the PVC units.

Appeared In Issue: September 2009

AVEVA Group plc

www.aveva.com

AVEVA Instrumentation
AVEVA Instrumentation is a software application that can handle the specification, design and maintenance of all plant instrumentation and control systems. It can be used as a stand-alone product or integrated with the company’s other applications. It incorporates all plant engineering and plant design management system (PDMS) 3-D design data within a single model database. The data are fully controlled, and can be used across all phases of engineering, supporting fast, error-free plant design.

Appeared In Issue: September 2009

Barben

www.bat4ph.com

Platinum Bullet oxidation-reduction potential sensor
The Platinum Bullet oxidation-reduction potential (ORP) sensor uses patented axial ion path (AIP) technology to withstand harsh environments. It is available in a variety of models for inline, hot-tap, or quick-change fittings, and operates at temperatures up to 140°C and pressures exceeding 3,000 psi.

Appeared In Issue: September 2009

ARC Advisory Group

www.arcweb.com

Workshops
Industry experts will present free educational workshops covering plant performance benchmarking, operations and maintenance (O&M) information handover, and asset performance management (APM). The benchmarking workshop will discuss how to use industry tools to collect and report benchmarking information, and how an owner/operator can take advantage of these data and other metrics to gain a competitive edge in global markets. The O&M meeting will report on guidelines for more effective transfer of information needed for operations and maintenance. The APM session will present the company’s evolving model for APM, and will provide practical strategies for improving the operating and availability performance of assets, including physical equipment as well as “hidden assets” that drive ultimate performance.

Appeared In Issue: September 2009

MOXA Americas, Inc.

www.moxa.com

ioLogik W5340 Active GPRS I/O
The ioLogik W5340 Active GPRS I/O is an active Ethernet input/output (I/O) device that uses general packet radio service (GPRS) technology. It is suitable for remote monitoring and alarm applications in hard-to-wire locations, such as along pipelines and at unmanned sites. Used with the manufacturer’s Active object linking and embedding for process control (OPC) server, it can create a remote monitoring and alarm system in GPRS dynamic Internet protocol (IP) environments. It supports the standard OPC protocol, as well as active (“push”) communications between ioLogik products and human-machine interface/supervisory control and data acquisition (HMI/SCADA) systems. It features data logging and active time-stamped alarm messaging.

Appeared In Issue: September 2009

Universal Analyzers

www.universalanalyzers.com

270/NH3 gas sample probe and ammonia converter
The 270/NH3 gas sample probe and ammonia converter provides both a converted and an unconverted sample stream. This provides a way to measure the ammonia slip that is normally found at the exit of a selective catalytic reduction (SCR) unit using the dual NOx differential method. By combining the sample probe and ammonia converter, a single unit provides both filtration and conversion at the source of measurement. The device comes with an aggressive blowback (filter purging) and a calibration-gas inlet port for compliance with U.S. Environmental Protection Agency regulations. Proper temperatures are maintained to prevent cold spots and loss of ammonia during conversion. A separate ammonia converter is also available for use with an existing sample probe.

Appeared In Issue: September 2009

Weidmuller, Inc.

www.weidmuller.com

Wave TTA module
The Wave TTA module functions as a signal isolator, transmitter, converter, linearizer, and trip amplifier. It accepts all common types of analog direct current (DC) inputs, such as temperature and frequency. All output types (e.g.,bipolar) can be set on this 45-mm-wide unit. Input/output configuration changes may be performed on a PC with free, downloadable software. The module can be mounted in any location using almost any power supply. Its –40°F to 158°F operating temperature range allows mounting in either a factory or field enclosure.

Appeared In Issue: September 2009

Palmer Wahl

www.palmerwahl.com

Fever Alert products
Fever Alert products are designed to perform rapid screening of individuals in public places for elevated body temperatures in an effort to slow the spread of flu viruses. Products include a hand-held infrared thermometer, a thermal-imaging camera, and a high-resolution thermal imaging system. The devices automatically detect the hottest temperature on a subject, tracking critical temperature differences in real time. When a high temperature is detected, the unit produces both audible and visible alarms.

Appeared In Issue: September 2009

Magnetrol International

www.magnetrol.com

Digital E3 Modulevel liquid-level displacer transmitter
The Digital E3 Modulevel liquid-level displacer transmitter is an intrinsically safe two-wire instrument that uses the principle of buoyancy to detect and convert changes in liquid level into a stable output signal. The linkage between the level-sensing element and the output electronics has a simple mechanical design and construction. The transmitter’s vertical inline design makes the instrument lightweight and simplifies installation. It is available in a variety of configurations and pressure ratings. It has microprocessor-based electronics with 4–20-mA HART or Foundation fieldbus output. It supports the FDT/DTM standard, and a PACTware PC software package provides additional configuration and trending capabilities.

Appeared In Issue: September 2009

ASCO

www.ascovalve.com

8262/8263 Series two-way direct-acting solenoid valves
8262/8263 Series two-way direct-acting solenoid valves can be used to control the flow of air, water, or light oil. They are available in normally closed, brass and stainless steel constructions for pipe sizes of 0.125 in., 0.25 in., and 0.375 in. The online configuration tool enables a customer to quickly model a valve to meet a set of specific requirements. It then displays the list price, availability, 3-D computer-aided design (CAD) drawings, and specifications for the configured product.

Appeared In Issue: September 2009

Northwire

www.northwire.com

Multi-pair Foundation fieldbus M-EZ cables
Multi-pair Foundation fieldbus M-EZ (Marshaling EZ) cables are FF-844 certified by the Fieldbus Foundation. The cables are part of the DataCELL Foundation line and are engineered with up to 24 individually foil-shielded pairs, with an extruded polyvinyl chloride (PVC) binder over each pair, all in a single cable. Installation is quick and easy, and requires no shrink tubing. The line also features single-pair cables. Both types of cable are available with an optional ground wire. The cables’ characteristic impedance Z0 is controlled to be 100 Ω ±10 Ω at 31.25 kHz.

Appeared In Issue: September 2009

Sealevel Systems

www.sealevel.com

Relio 9 reduced instruction set computer
The Relio 9 reduced instruction set computer (RISC) has a 32-bit Advanced RISC Machines (ARM) instruction set and is available with up to 256 MB RAM and 256 MB flash memory. Standard input/output (I/O) interfaces include Ethernet, serial, USB, CAN bus, digital, and analog. For local or remote I/O expansion, it connects to the manufacturer’s Sea I/O modules via a dedicated RS-485 expansion port and communicates via an RS-485 Modbus remote terminal unit (RTU). It is housed in a small, rugged enclosure that is suitable for mounting almost anywhere. It has a –40°C to 85°C operating temperature range.

Appeared In Issue: September 2009

Ametek

www.ametek.com

Model 5100-NCM gas analyzer
The Model 5100-NCM (for Non-Contact Moisture) gas analyzer uses tunable-diode laser absorption-spectroscopy technology to measure carbon dioxide (CO2) and moisture/methane (CH4) in natural gas and hydrocarbon streams. Its limit of detection is in the low-ppm range. It has fully enclosed optics and sample conditioning, onboard moisture verification, and all-digital signal processing. This rugged, compact unit is available in an IP-65 and NEMA 4 enclosure with both Modbus and Ethernet analog and digital connectivity.

Appeared In Issue: September 2009

Adalet

www.adalet.com

XDHI dual-sided instrument housing
With a 2.25-in. internal diameter, the compact XDHI dual-sided instrument housing accommodates small instruments and control devices without the wasted space of a larger unit. The enclosure has back-to-back chambers that are separated by a solid 0.1875-in.-thick dividing wall. Solid or glass covers are available as either a standard flat cover or a domed version with added depth. The housing is certified by Underwriters Laboratories (UL), Canadian Underwriters Laboratories (cUL), and ATEX for global applications. The enclosures can be customized with internal blind-drilled and tapped mounting holes. They can be manufactured with a cast-in company logo and painted to match a company’s color scheme.

Appeared In Issue: September 2009

OleumTech

www.oleumtech.com

LM5000 series WIO high-level switches
LM5000 series WIO high-level switches use industrial liquid-level sensing to prevent spillage and overflow. These submersible switches are integrated with a battery-powered radio frequency (RF) transmitter that immediately issues wireless alarms when a setpoint level is reached. They are self-contained and available in side-mount and top-mount packaging. They are suitable for point-level sensing of chemicals, petroleum, and solvents. All switches in the series are certified as intrinsically safe for use in hazardous areas.

Appeared In Issue: September 2009

iKey

www.ikey.com

Wireless Keyboards
These completely sealed, intrinsically safe wireless keyboards meet the requirements for operation in hazardous locations and are approved by Factory Mutual (FM) for Class I, II, and III, Division I, Groups C, D, E, F and G. The DW-5K-IS requires three AA batteries and a USB connector that is in the host computer and thus isolated from the hazardous location. It has an integrated pointing device and measures 14.97 in. wide by 6.61 in. high by 1.91 in. deep. The BT-87-TP-IS is a Bluetooth-compatible, submersible keyboard that does not require a USB connector if the host computer is also Bluetooth-compatible. It uses two AA batteries, has an integrated touchpad, and measures 12.01 in. wide by 7.75 in. high by 2.03 in. deep. Both keyboards have a 30-ft range and are built with a sealed, industrial silicone rubber keypad and a rugged ABS polycarbonate case. Each keyboard meets NEMA 4X specifications, and is capable of withstanding dirty, wet and corrosive environments.

Appeared In Issue: September 2009

Martel Electronics

www.martelcorp.com

BetaGauge PI and BetaGauge PI Reference Class digital pressure test gauges
BetaGauge PI and BetaGauge PI Reference Class digital pressure test gauges have been equipped with a data-logging feature and BetaLOG data-logging software. BetaLOG is an easy-to-use, low-cost application that configures the gauge to operate in download mode (computer configuration) or ad hoc demand mode (field configuration). The download operational mode allows many configuration settings, including multiple interval selection options from 1 s to 1 h, and its data-logging runs range from a few seconds to several weeks. Data can be captured at defined intervals continuously, above or below preset values, or when noise or transients in the pressure signal are detected. Six types of data can be collected: interval end, average, minimum, maximum, median, and a combination of average/minimum/maximum. Demand-mode data logging allows the user to set up and initiate data logging in the field using a keypad. The unit has a rugged stainless steel, rubber-booted housing, a durable faceplate, an IP-65 rating, and a long battery life.

Appeared In Issue: September 2009