A&WMA's 98th Annual Conference And Exhibition
June 21 - 24, 2005 Minneapolis, MN
Firm Offers Toxic Air Pollutant Analysis and Monitoring
Located in Ventura, CA, this full-service air-quality laboratory provides high-quality and cost-effective analysis of toxic air pollutants and monitoring to industry and government agencies. Established in 1993, the firm is equipped with a complete inventory of modern state-of-the-art laboratory equipment. Its staff has made many professional contributions through published literature and is active in ongoing research. Atmospheric Analysis & Consulting (AAC)
Appeared In Issue: June 2005
Atmospheric Analysis & Consulting (AAC)
Environmental Management Software Is Comprehensive
Specializing in converting raw data into useable information, IMPACT is a software system for the management of environmental data and related processes. Data can be entered via a user-friendly, web-based interface or IMPACT’s data import tool. Streamlined reporting and graphing tools, systematic action tracking and automatic e-mail notification, as well as escalation features allow for a responsive management of environmental processes. IMPACT offers a broad range of functional content that can be applied across a wide range of industries. Compliance, ISO 14001, permits, licenses, and other obligations, as well as sustainability processes are all supported by the software.
Appeared In Issue: June 2005
BMS Solutions
www.bmssolutions.com
This System Effectively Manages EHS Compliance
The Enviance System is an Internet-based system for the collection, distribution, analysis and reporting of environmental, health and safety (EHS) data and information. It offers a comprehensive, standards-based platform for flexible, cost effective EHS compliance management. Because of the attention to data portability, the Enviance System allows firms to fully configure the system to meet their specific requirements and complete end-to-end compliance needs. It is ideal for organizations facing extensive and complex compliance requirements in air, water, and waste, as well as a customary blend of health and safety issues
Appeared In Issue: June 2005
Enviance
www.enviance.com
Get Dependable Gas Measurements with These Analyzers
The Sensor-e series of gas analyzers use proven analytical techniques, coupled with state-of-the-art microprocessor technology to provide accurate and dependable gas measurements. The multitasking software gives realtime indication of a large number of operational parameters and provides automatic alarms if diagnostic limits are exceeded. All instruments of the Sensor-e series include an extensive built-in data acquisition capability using the analyzer’s internal memory. This allows the logging of multiple parameters (up to 1 million records), including averaged or instantaneous concentration values, calibration data and operating parameters such as flow, pressure and lamp intensity. All instruments in this series offer Ethernet connectivity, which allows for remote access to all analyzer functions and data. Stored data is easily retrieved through the serial or Ethernet port via sensor-e.com or from the front panel, allowing operations to perform predictive diagnostics and enhanced data analysis by tracking parameter trends.
Appeared In Issue: June 2005
Teledyne Monitor Labs
www.teledyne-ml.com
This Analyzer Was Designed for the Low NOx Market
The Model 2020 Chemiluminescent NOx analyzer measures from 10 ppm or lower up to 500 ppm of NO, NO2, and NOx with a resolution of 0.01 ppm. A dual-range version is also available offering 0–500 ppm and 0–3,000 ppm. The analyzer has been developed specifically to address the performance requirements of the low NOx market with respect to drift, noise, and elimination of interference from CO2 and water. All digital electronics provide high accuracy and less noise. The front-panel display of converter temperature and chamber pressure allows visual confirmation of operating parameters. A slide-out drawer provides complete access to plug-and-play replaceable components.
Appeared In Issue: June 2005
Liston Scientific Corp.
www.listonscientific.com
Data Acquisition Products Get Connected with Ethernet
The Advantech Adam 5000/TCP enables the integration of this firm’s data acquisition product with state-of-the art communications technology that uses Ethernet (TCP-IP) as a transmission medium. The unit can be used with the EMC Station Manager CEMS/DAS and EMC Station Manager data logger software for ambient air quality and meteorological monitoring, thus benefitting from high data rates that are inherently possible in Ethernet communications.
Appeared In Issue: June 2005
Environmental Monitoring Co.
www.emcslo.com
Firm Provides Air Pollution Control Retrofit Services
This company provides services for retrofitting emission control equipment on existing waste-to-energy and industrial boiler installations. The retrofit services center on the installation of the firm’s spray-dry scrubber systems for controlling acid gases emitted from incinerators and boilers. Other equipment, such as electrostatic precipitators or fabric filters, may also be used in conjunction with the scrubber or as stand-alone systems. The A&WMA’s 98th Annual Conference and Exhibition June 21 – 24, 2005 Minneapolis, MN CEP June 2005 www.cepmagazine.org 21 organization can also perform the retrofits on a turnkey basis, from the demolition of the outdated equipment to the design, manufacture, installation and startup of the new system.
Appeared In Issue: June 2005
McGill AirClean LLC
www.mcgillairclean.com
NOx Analyzer Comes in a Compact and Modular Design
The 800 series NOx analyzers feature a membrane vacuum pump and thermal ozone scrubber integrated inside of the unit’s housing for a compact, modular and efficient design. The CLD 844 CM h NOx and NH3 analyzer incorporates a heated sample inlet, dual converters and dual reaction chambers to accurately measure and display NOx and NH3 simultaneously.
Appeared In Issue: June 2005
Eco Physics, Inc.
www.ecophysics-us.com
Company Specializes in Mercury Emissions Control
Providing testing and engineering services for mercury emissions control to utility clients, EPRI and DoE, this company has more than 30 professional mercury specialists on staff. With the introduction of multi-pollutant regulations, the firm is developing system-wide mercury control strategies. Services include: characterization of mercury emissions; optimization of current air pollution control systems to maximize multi-pollutant control; identification of suitable mercury control technologies; conceptual design and layout of mercury control equipment; and estimation of operating and capital costs.
Appeared In Issue: June 2005
URS Corp.
www.urscorp.com
Firm Offers Extensive Air Quality Improvement Services
This firm offers in-depth experience in all phases of air quality management, from conducting emissions inventories and developing monitoring programs, to preparing permit applications and designing and building pollution control systems. State-of-the-art equipment, coupled with strategic modeling and risk assessment techniques, enable the company to evaluate problems accurately and engineer workable solutions to complex, and potentially costly, environmental issues.
Appeared In Issue: June 2005
Environmental Resources Management
www.erm.com
Ozone Treatment System Remediates Groundwater
Self-contained and padmounted, the Model GWR1000X ozone treatment system for groundwater treatment features a PLC-controlled, 120-V adjustable touchpad. It can monitor for ozone leaks at unattended sites, as well as handle multiple zones. The system can be easily adapted to customer requirements.
Appeared In Issue: June 2005
CEC/Aquadox
www.aquadox.com
In Situ, Multicomponent FTIR Gas Analyzer Is Versatile
The GASMET FTIR In-Situ series includes industrial multicomponent gas analyzers for continuous monitoring applications. The GASMET In-Situ 5.0 incorporates a Fourier transform infrared spectrometer, a temperature-controlled sample cell directly inserted into the sample gas flow and signal processing electronics. The analyzer is fully equipped for fixed installations, and offers versatility and high performance for a wide range of applications.
Appeared In Issue: June 2005
Air Quality Analytical, Inc.
www.airqa.com
Remove Mercury From Liquids with These Sorbents
The Chromosorb QSR series of high performance mercury sorbents are proprietary materials engineered to remove mercury from liquid process and waste streams. This series combines advanced surface science knowledge with classical fluid separation dynamics. They are capable of reliably removing mercury from industrial and municipal water and oil to parts per billion or even parts per trillion residual levels. Elemental, ionic, or organic forms of mercury may be treated with Chromosorb QSR products. They are available in a powder form amenable for use in many existing treatment systems with little or no additional investment needed. Pelletized or custom shapes may also be made available on request.
Appeared In Issue: June 2005
Celite Corp.
www.celite.com
Datalogger Takes on a Multitude of Applications
The rugged and reliable CR1000 datalogger retains the versatility of earlier dataloggers with a detachable wiring panel, separate power supply and optional keyboard display. It features increased memory, more measurement channels and an RS-232 port for communication. When used as part of a data acquisition system, the CR1000 provides the measurement and control functions. A complete system would include a power supply, weatherproof enclosure, sensors, programming/ communications software and communications peripherals.
Appeared In Issue: June 2005
Campbell Scientific, Inc.
www.campbellsci.com
Gas Analysis Sampling System Handles High Flows
The line of GASS gas analysis sampling systems prepare samples for analysis by removing water, acid mists and ash without altering the concentrations of analytes. New to this line is the GASS-2040 system, with a NEMA 4x stainless steel enclosure, dual-temperature controllers to eliminate acid mist, dual dryers to accommodate high sample flows and integral stack mounting capabilities. The unit eliminates heated sample lines by connecting directly to the probe and drying the sample completely before transporting it to the ground.
Appeared In Issue: June 2005
Perma Pure LLC
www.permapure.com